Philips builds AI into its CT 5300 and Rembra CT scanners, used by radiographers and radiologists in hospital imaging departments; the AI features are part of the scanner, not separate applications. Philips says Precise Image is a reconstruction mode that uses a convolutional neural network to produce lower-noise images from lower-dose scans, which it says allows up to 80% less dose, and that Precise Position uses an AI-enabled camera to recommend table height and scan start and end positions. Other 'Precise' applications plan scan ranges, label vertebrae, align brain images and correct cardiac motion. Philips presents Rembra CT, launched in March 2026 and CE marked, as using AI-enabled smart workflows and a detector designed to work with AI. The radiographer positions the patient and runs the scan, and the radiologist reads the images; Philips says the dose to use should be set with a radiologist and a physicist. Philips describes these as functions of the CT system's own software and names no cloud processing for them.

Website besuchen

Transparenz-Score

Gewichtet über vier Säulen · aktualisiert October 20, 2026

Gesamtnote
47% gewichtet
ABCDF
Modell
—
Noch nicht bewertet
Infrastruktur
—
Noch nicht bewertet

Funktionen

Deep Learning Image Reconstruction
Ai Patient Positioning
Automated Scan Planning
Automated Image Reformatting
Cardiac Motion Correction

Anbieterinformationen

Vollständige Informationen zum Anbieter/Provider dieser KI-Anwendung

PhilipsAlle Produkte ansehen →
Philips Medical Systems Nederland B.V.(Handelsname: Philips)
Kontaktinformationen
www.philips.com/healthcare
Registrierte Adresse
Veenpluis 6, Best, Noord-Brabant, 5684 PC, NL

Anbieterinformationen gemäß EU AI Act

Verifizierungsstatus:
Unverified
(Zuletzt verifiziert: October 20, 2026)
Philips Medical Systems Nederland B.V.(Handelsname: Philips)
Veenpluis 6, Best, Noord-Brabant, 5684 PC, NL
Compliance-Dokumente
CE-Kennzeichnung: Certified
Philips states that the dose reduction Precise Image allows depends on the clinical task, patient size and anatomical location, that the appropriate dose should be set in consultation with a radiologist and a physicist, and that its dose and noise figures come from phantom tests; it also states that patients below the age of 18 are not supported by Precise Position (https://www.documents.philips.com/assets/20250204/8bb841ff40794fa396f2b27a0146df1f.pdf, CT 5300 brochure, Apr 2025, read 2026-10-20). For SmartSpeed Precise, Philips gives its speed and sharpness claims relative to its own SENSE and Compressed SENSE imaging and says it is not available for Prodiva and Multiva systems (https://www.documents.philips.com/assets/20251209/bf15c9ca7894495e9ee6b3ae00b14ed4.pdf, Oct 2025, read 2026-10-20). Philips notes that features may not be available in every market. No instructions for use were found publicly.

Lieferkettennetzwerk

Visuelle Darstellung der digitalen Lieferkettenbeziehungen des Anbieters

Compliance & Risiken

Erhalten Sie Einblicke in Risiken, indem Sie Bewertungen für diese KI-Anwendung durchführen.

Arbeiten Sie bei Philips? Übernehmen Sie diesen Eintrag, um die Daten zu korrigieren oder zu vervollständigen.

Hinzugefügt: October 20, 2026
Aktualisiert: October 20, 2026

Bereit, KI-Anwendungen zu verwalten?

Verfolgen, bewerten und steuern Sie Ihre KI-Anwendungen mit Anove.

Anove-LogoAnove-LogoAnove International B.V.

Wir helfen Organisationen, KI-Anwendungen verantwortungsvoll zu entdecken und zu verwalten. Ihre vertrauenswürdige Quelle für KI-Governance und Compliance.

Schnellzugriffe

  • Verzeichnis durchsuchen
  • FAQ
  • KI-Karten nach Branche
  • Anmelden

Ressourcen

  • Dokumentation
  • Status
  • Anove.ai

Rechtliches

  • Datenschutzerklärung
  • AGB
  • Responsible Disclosure
  • KI-Rechtshinweis
  • Sicherheitsrichtlinie

© 2026 Anove International B.V. Alle Rechte vorbehalten.