AI Application
Laag vertrouwen

BoneXpert is software that reads a child's hand X-ray, used in hospitals by radiologists, radiographers, endocrinologists and nurses. The vendor says it determines bone age autonomously by the Greulich-Pyle and Tanner-Whitehouse 3 methods, and also reports a Bone Health Index and Percent Adult Height, for patients up to 21 years old. It automatically rejects images it cannot analyse, such as a wrong hand pose, heavy post-processing or abnormal bone morphology, and the vendor says a radiologist should then assess the image. The vendor says the analysis needs no supervision by an expert, but also that its results must not be used as the sole basis for diagnosis, so a clinician interprets the reported bone age. BoneXpert Server runs on hospital hardware and exchanges images with the PACS and RIS; BoneXpert Online processes anonymised images on Visiana's own server, whose location is not stated. Each analysis makes a handshake with a central licence server.

Bezoek website

Transparantiescore

Gewogen over vier pijlers · bijgewerkt October 20, 2026

Totaalscore
33% gewogen
ABCDF
Model
—
Nog niet beoordeeld
Infrastructuur
—
Nog niet beoordeeld

Functionaliteiten

Bone Age Assessment
Bone Health Index
Percent Adult Height Estimation
Image Quality Rejection

Leveranciersinformatie

Volledige informatie over de leverancier/provider van deze AI-applicatie

VisianaBekijk alle producten →
Visiana ApS(Handelsnaam: Visiana)
Contactinformatie
bonexpert.com
Geregistreerd adres
Fremtidsvej 1, Hørsholm, Capital Region of Denmark, 2970, DK

Leveranciersinformatie volgens de EU AI Act

Verificatiestatus:
Unverified
(Laatst geverifieerd: October 20, 2026)
Visiana ApS(Handelsnaam: Visiana)
Fremtidsvej 1, Hørsholm, Capital Region of Denmark, 2970, DK
Nalevingsdocumenten
CE-markering: Certified
Gebruiksinstructies
Visiana states BoneXpert is for DICOM hand radiographs of patients up to 21 years, used by healthcare professionals; bone age ranges are 0-19 years (boys) and 0-18 (girls) for Greulich-Pyle and 2-16.5 (boys) and 2-15 (girls) for TW3; it is 'Contraindicated for use in children with achondroplasia'; images with severely abnormal anatomy or excessive post-processing may not be accepted (about 1%); and 'BoneXpert results must not be used as the sole basis for diagnosis' (https://bonexpert.com/ce-mark/, read 2026-10-20). The BoneXpert Online IFU v1.1 (May 2021) adds that ethnicity is not considered, that radiographs recorded on film must not be analysed, that the Bone Health Index is mainly for research use, and that rejected images should be assessed by a radiologist (https://visiana.zohodesk.eu/portal/en/kb/articles/bonexpert-online-instructions-for-use, read 2026-10-20).
Naleving & risico

Krijg inzicht in risico's door beoordelingen uit te voeren op deze AI-applicatie.

Werk je bij Visiana? Claim deze vermelding om de gegevens te corrigeren of aan te vullen.

Toegevoegd: October 20, 2026
Bijgewerkt: October 20, 2026

Klaar om AI-applicaties te beheren?

Volg, beoordeel en beheer je AI-applicaties met Anove.

Anove-logoAnove-logoAnove International B.V.

We helpen organisaties AI-applicaties op een verantwoorde manier te ontdekken en beheren. Uw betrouwbare bron voor AI-governance en compliance.

Snelle links

  • Directory bekijken
  • FAQ
  • AI-kaarten per sector
  • Inloggen

Bronnen

  • Documentatie
  • Status
  • Anove.ai

Voorwaarden

  • Privacybeleid
  • Algemene voorwaarden
  • Responsible disclosure
  • AI-juridische kennisgeving
  • Beveiligingsbeleid

© 2026 Anove International B.V. Alle rechten voorbehouden.